Factory-audited suppliers Class certificates from the maker · CCS · BV · ABS · DNV · LR · NK · KR · RINA · RS Est. 2015 · Taizhou, Jiangsu
sales@hiqool.com +86 523-8762-5500
Request Quote
Marine Ventilation · 25 Models

Marine Ventilation Fans — Axial, Centrifugal & Blower Systems

CCS-approved marine ventilation fans: axial fans, centrifugal fans, and blower units for engine rooms, cargo holds, accommodation, and hazardous areas. 25 models available.

CE · ISO 9001 (Manufacturer) Certificates with Goods Hicool Supply
25 Models Available
25–250 Power
CE · ISO Held by Manufacturer
14–28 Days Typical Delivery

Need CCS-Approved Ventilation Fans for Engine Room, Cargo Hold, or Accommodation?

Marine ventilation is a class requirement, not an option — and every space on a vessel has specific airflow, pressure, and fire-safety requirements that general industrial fans cannot meet. hicool supplies 25 configurations of CCS-approved marine axial fans, centrifugal fans, and blowers designed for engine room ventilation, cargo hold air exchange, accommodation HVAC supply, and pump room gas extraction.

🔒 Log in or Register to view pricing

Marine Ventilation Fans — Axial, Centrifugal & Blower, CCS Approved

Our marine fan catalogue covers three main categories across 25 product configurations: axial-flow fans for high-volume engine room and cargo hold ventilation, centrifugal fans for duct-based HVAC and high-pressure extraction systems, and portable/fixed blowers for tank ventilation and emergency use. All products are designed per CCS Marine Product Rules and can be supplied with the manufacturer’s BV, ABS, DNV, LR, NK, KR, RINA or RS certificates as required by class.

Axial fans are available in direct-drive and belt-drive configurations, with impeller diameters from 300 mm to 1,600 mm. Centrifugal fans include single-inlet and double-inlet designs with backward-curved or forward-curved impellers for different pressure/flow requirements. All fans feature marine-grade IP56 motors, vibration-dampening mounts, and corrosion-resistant construction (epoxy-coated steel or optional stainless steel for chemical tankers).

Fire dampers, silencers, anti-vibration mounts, and transition ductwork are available as accessories. We supply both individual fans and complete ventilation system packages matched to the vessel’s ventilation schedule.

Watch: Review a Centrifugal Fan Assembly

This video shows centrifugal equipment examples, not the entire axial and centrifugal fan range. Fabrication footage is not a performance test.

Send the airflow, pressure, duct layout and power supply. Request a review: sales@hiqool.com

English captions available. AI-generated English narration.

Key Specifications

CCS BV (on request)
  • Fan Types — Axial, centrifugal (single/double inlet), portable blower
  • Air Volume Range — 500 m³/h to 120,000 m³/h
  • Static Pressure — Up to 3,000 Pa (centrifugal); up to 800 Pa (axial)
  • Impeller Diameter — 300 mm to 1,600 mm (axial); custom (centrifugal)
  • Motor — Marine-duty IP56, Class F insulation, anti-condensation heaters
  • Material — Epoxy-coated carbon steel (standard); SS304/SS316L (optional)
  • Fire Safety — Fire damper integration available per SOLAS Ch. II-2
  • Noise Level — Sound attenuation silencers available for accommodation zones

Product Range Overview

TypeAir Volume (m³/h)Static Pressure (Pa)ApplicationFOB Range (USD)
Axial Fan (Direct Drive)2,000–80,000100–500Engine room supply/exhaust$800–$8,000
Axial Fan (Belt Drive)5,000–120,000200–800Cargo hold, large E/R$1,500–$15,000
Centrifugal (Single Inlet)500–30,000500–3,000HVAC duct, accommodation$600–$6,000
Centrifugal (Double Inlet)2,000–60,000500–2,500High-volume HVAC$1,200–$12,000
Portable Blower1,000–8,000100–300Tank entry, emergency$500–$2,000
Explosion-Proof Fan1,000–40,000200–1,500Pump room, cargo area$2,000–$20,000

Axial vs Centrifugal — Which Fan Type Do You Need?

FeatureAxial FanCentrifugal Fan
Best ForHigh volume, low pressureMedium volume, high pressure
Typical UseEngine room, cargo hold, open spacesDuctwork, HVAC, accommodation
Pressure CapabilityUp to ~800 PaUp to ~3,000 Pa
Space EfficiencyIn-line mounting (compact)Requires scroll housing (larger)
NoiseHigher at same duty pointGenerally quieter
CostLowerHigher

Rule of thumb: Use axial fans for engine room and cargo hold ventilation where high air volume matters more than pressure. Use centrifugal fans for ducted HVAC systems, accommodation zones where noise is critical, and any system requiring static pressure above 500 Pa.

Common Applications

  • Engine room supply and exhaust ventilation (SOLAS requirement)
  • Cargo hold ventilation for bulk carriers and general cargo vessels
  • Accommodation HVAC air handling (centrifugal type with silencers)
  • Pump room gas extraction on tankers (explosion-proof type)
  • Emergency/portable tank ventilation for confined space entry
  • Galley exhaust and laundry ventilation

Recent Supply Example

A shipyard in India ordered a complete ventilation fan package for a 32,000 DWT chemical tanker: 6 × axial fans (engine room), 4 × centrifugal fans (accommodation HVAC), 2 × explosion-proof axial fans (pump room), and accessories (fire dampers, silencers, flex connectors). All CCS-certified. Delivered FOB Shanghai within 40 days. Total package value: ~USD 52,000.

Why Source Through hicool?

  • Direct factory pricing — typically 30–50% below European equivalents
  • CCS type approval standard (held by the manufacturer); BV, ABS, DNV, LR, NK, KR, RINA or RS certificates on request
  • Complete documentation: performance curves, noise data, GA drawings, class certs
  • Express delivery: 25–40 days for standard sizes; 45–60 days for custom/explosion-proof
  • System packages: matched fan sets per vessel ventilation schedule, reducing procurement effort

Browse Ventilation Fans Products

View All Ventilation Fans →

📩 Need a quotation?
Send your requirements to sales@hiqool.com or request a quote online. We respond within 24 hours with pricing, lead time, and technical datasheets.

Model Comparison — 25 Models

Compare specifications across the full range. Click any model for detailed product page.

Model SKU Power Voltage Speed Diameter Frequency Airflow Noise Level Protection Classification HS Code Type Model
CK-100A Marine Circular Duct Fan — 50Hz HC-440301-011 25 W 220V 1ph 2450 RPM 100 mm 50Hz 160 m³/h ≤ 35 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-100A Marine Circular Duct Fan — 60Hz HC-440301-023 28 W 220V 1ph 2900 RPM 100 mm 60Hz 190 m³/h ≤ 36 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-100C Marine Circular Duct Fan — 50Hz HC-440301-012 40 W 220V 1ph 2600 RPM 100 mm 50Hz 250 m³/h ≤ 38 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-100C Marine Circular Duct Fan — 60Hz HC-440301-024 45 W 220V 1ph 3100 RPM 100 mm 60Hz 300 m³/h ≤ 39 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-125A Marine Circular Duct Fan — 50Hz HC-440301-013 36 W 220V 1ph 2350 RPM 125 mm 50Hz 280 m³/h ≤ 37 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-125A Marine Circular Duct Fan — 60Hz HC-440301-025 40 W 220V 1ph 2800 RPM 125 mm 60Hz 330 m³/h ≤ 38 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-125C Marine Circular Duct Fan — 50Hz HC-440301-014 55 W 220V 1ph 2500 RPM 125 mm 50Hz 370 m³/h ≤ 40 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-125C Marine Circular Duct Fan — 60Hz HC-440301-026 60 W 220V 1ph 3000 RPM 125 mm 60Hz 440 m³/h ≤ 41 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-160B Marine Circular Duct Fan — 50Hz HC-440301-015 55 W 220V 1ph 2300 RPM 160 mm 50Hz 420 m³/h ≤ 40 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-160B Marine Circular Duct Fan — 60Hz HC-440301-027 60 W 220V 1ph 2750 RPM 160 mm 60Hz 500 m³/h ≤ 41 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-160C Marine Circular Duct Fan — 50Hz HC-440301-016 80 W 220V 1ph 2450 RPM 160 mm 50Hz 560 m³/h ≤ 43 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-160C Marine Circular Duct Fan — 60Hz HC-440301-028 90 W 220V 1ph 2900 RPM 160 mm 60Hz 670 m³/h ≤ 44 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-200A Marine Circular Duct Fan — 50Hz HC-440301-017 75 W 220V 1ph 2200 RPM 200 mm 50Hz 660 m³/h ≤ 42 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-200A Marine Circular Duct Fan — 60Hz HC-440301-029 85 W 220V 1ph 2650 RPM 200 mm 60Hz 790 m³/h ≤ 43 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-200B Marine Circular Duct Fan — 50Hz HC-440301-018 100 W 220V 1ph 2350 RPM 200 mm 50Hz 830 m³/h ≤ 45 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-200B Marine Circular Duct Fan — 60Hz HC-440301-030 115 W 220V 1ph 2800 RPM 200 mm 60Hz 990 m³/h ≤ 46 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-250A Marine Circular Duct Fan — 50Hz HC-440301-019 120 W 220V 1ph 2150 RPM 250 mm 50Hz 1050 m³/h ≤ 45 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-250A Marine Circular Duct Fan — 60Hz HC-440301-031 135 W 220V 1ph 2550 RPM 250 mm 60Hz 1250 m³/h ≤ 46 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-250C Marine Circular Duct Fan — 50Hz HC-440301-020 160 W 220V 1ph 2300 RPM 250 mm 50Hz 1350 m³/h ≤ 48 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-250C Marine Circular Duct Fan — 60Hz HC-440301-032 180 W 220V 1ph 2750 RPM 250 mm 60Hz 1600 m³/h ≤ 49 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-315B Marine Circular Duct Fan — 50Hz HC-440301-021 160 W 220V 1ph 2100 RPM 315 mm 50Hz 1600 m³/h ≤ 48 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-315B Marine Circular Duct Fan — 60Hz HC-440301-033 180 W 220V 1ph 2500 RPM 315 mm 60Hz 1900 m³/h ≤ 49 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-315C Marine Circular Duct Fan — 50Hz HC-440301-022 220 W 220V 1ph 2250 RPM 315 mm 50Hz 2100 m³/h ≤ 50 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CK-315C Marine Circular Duct Fan — 60Hz HC-440301-034 250 W 220V 1ph 2700 RPM 315 mm 60Hz 2500 m³/h ≤ 51 dB(A) IP44 CCS / BV / ABS / DNV 8414.51 — —
CZT160 Marine Axial Flow Fan HC-170511-001 — — — — — — — IP55 CCS / BV / ABS 8414.59 Axial Flow Fan CZT160

Fan Selection Guide

1

Identify Compartment

Engine room (high volume), cargo hold (moisture control), accommodation (low noise), or hazardous area (Ex-proof required). Each has different class rule requirements.

2

Calculate Airflow

Engine room: air changes per SOLAS. Cargo hold: per cargo type ventilation requirements. We size fans from your ventilation plan or vessel GA.

3

Fan Type

Axial: high volume, low pressure — engine room supply/exhaust. Centrifugal: high pressure — long ductwork runs. Auxiliary blower: boiler forced draft.

4

Hazardous Area Rating

Cargo pump room: Ex d IIB T4 mandatory. Battery room: Ex d IIC T3. Standard compartments: non-Ex. Specify zone classification for correct motor selection.

Product Video

Video Coming Soon

A product video is being prepared. Subscribe to our YouTube channel to be notified.

How We Deliver

1

Send Your Requirements

Technical specifications, quantity, classification requirements, and delivery schedule. We respond with a detailed quotation within 24 hours.

2

Confirm & Order

Review our quotation with technical drawing, delivery schedule, and payment terms. We confirm factory slot upon deposit.

3

Factory Inspection

Full dimensional check, function test, and quality inspection before packing. Photo report included. Third-party or class witness inspection on request.

4

Ship & Support

Export packing, FOB/CIF delivery, complete documentation (CE, test report, O&M manual). Installation support and spare parts available.

Frequently Asked Questions

SOLAS Chapter II-2 requires: (1) fire dampers at fire zone boundaries; (2) quick-closing arrangement for engine room ventilation; (3) reversible airflow for supply/exhaust dual-duty; (4) explosion-proof motors in cargo pump rooms. Our fans comply with all requirements and carry CCS type approval confirming SOLAS compliance.

Need Help Selecting the Right Model?

Send us your product specifications and requirements. Our engineers will recommend the optimal solution and provide a detailed quotation within 24 hours.

Request Quotation
Factory Direct Verified manufacturers
Manufacturer Certificates Class / CE / ISO 9001, supplied with goods
14–28 Days FOB Chinese port
T/T or L/C Flexible payment
Qiangbin Zhu - Founder, Hicool Machinery

Qiangbin Zhu — Founder, Hicool Machinery

10+ years sourcing marine and industrial equipment from China's manufacturing base. Direct factory relationships, quality inspection, and complete documentation for classification society approval. Direct contact: sales@hiqool.com