DLS Series Side-Blow Coolers — WKDL Narrow-Space Evaporators
WKDL DLS Series side-blow unit coolers for narrow corridors, tunnel freezers, and space-constrained installations. 7 models with lateral air discharge.
How Do You Cool a Narrow Corridor or Tunnel Without Blocking the Passage?
Ceiling coolers need headroom that narrow corridors and processing tunnels often lack. Floor units block forklift lanes. The WKDL DLS Series side-blow evaporators mount flat against a wall and discharge air horizontally across the room, delivering effective cooling in spaces as narrow as 2 metres without sacrificing any usable floor or overhead clearance.
WKDL DLS Series — Side-Blow Evaporators for Narrow Spaces
The DLS Series is designed for applications where conventional ceiling or floor evaporators simply do not fit. Seven models span 1.5 kW to 12.0 kW, with a slim wall-mount profile (typically 250–400 mm depth) that keeps the unit tight to the wall while directing chilled air sideways across the room. This makes the DLS ideal for processing corridors, pre-cooling tunnels, packaging line enclosures, and ante-rooms between temperature zones.
All DLS units use copper tube / aluminium fin coils with fin spacing options of 4.5 mm, 6 mm, and 9 mm. Electric defrost is standard. The compact form factor uses single-row or dual-row fan arrangements to maintain a shallow profile while still achieving effective air throws of 4–10 metres. Wall-mount brackets are included, and optional ceiling-suspension kits are available for corridor installations where wall space is occupied by racking.
The DLS line is popular in food processing plants, pharmaceutical clean rooms, flower cold storage corridors, and supermarket display-adjacent buffer zones throughout Southeast Asia, Eastern Europe, and Africa.
Key Specifications
CE (Manufacturer’s Declaration)
Manufacturer’s ISO 9001
- Operating Temperature — 0 °C to −25 °C
- Cooling Capacity Range — 1.5 kW (DLS-15) to 12.0 kW (DLS-120)
- Air Discharge — Side-blow horizontal, 4–10 m effective throw
- Unit Depth — 250–400 mm (slim wall-mount profile)
- Coil Construction — Copper tubes, hydrophilic aluminium fins
- Fin Spacing — 4.5 mm / 6 mm / 9 mm
- Defrost Method — Electric defrost standard
- Fan Motor — External rotor, IP54, 220 V / 380 V 50 Hz
- Refrigerants — R404A, R507A, R22, R134a
Model Range
| Model | Capacity (kW) | Air Flow (m³/h) | Fan Config | Unit Depth (mm) |
|---|---|---|---|---|
| DLS-15 | 1.5 | 1,200 | 1 × 250 mm | 250 |
| DLS-25 | 2.5 | 2,000 | 1 × 300 mm | 280 |
| DLS-40 | 4.0 | 3,200 | 2 × 250 mm | 300 |
| DLS-60 | 6.0 | 4,800 | 2 × 300 mm | 320 |
| DLS-80 | 8.0 | 6,500 | 2 × 350 mm | 350 |
| DLS-120 | 12.0 | 9,000 | 3 × 350 mm | 400 |
DLS (Side-Blow) vs DL (Ceiling) — Which Do You Need?
| Feature | DLS Side-Blow | DL Ceiling |
|---|---|---|
| Mounting | Wall-mount, side discharge | Ceiling-mount, downward discharge |
| Room Shape | Narrow corridors, tunnels (2–6 m wide) | Standard rooms (4–12 m wide) |
| Headroom Needed | Minimal (mounts at any height) | 300–600 mm below ceiling |
| Air Throw | 4–10 m horizontal | 6–15 m downward/forward |
| Capacity Range | 1.5–12 kW | 1.0–21 kW |
| Temp Range | 0 to −25 °C | +5 to −25 °C |
Rule of thumb: If your room is narrower than 4 metres or ceiling height is restricted, use the DLS. For standard rectangular cold rooms with adequate ceiling clearance, the DL is more cost-effective.
Common Applications
- Processing corridors between production and cold storage areas
- Pre-cooling tunnels for fruit and vegetables before packing
- Narrow ante-rooms and air-lock spaces between temperature zones
- Packaging line enclosures requiring side-directed cooling
- Small pharmaceutical storage rooms with limited ceiling access
Recent Supply Example
A fruit export packing facility in Thailand ordered 12 × DLS-60 units for pre-cooling tunnels (3 m wide × 25 m long). Units were wall-mounted at 2.5 m height with 6 mm fin spacing for the high-humidity fresh produce environment. Delivered FOB Shanghai within 14 days at approximately USD 850 per unit. Total project value: ~USD 10,200.
Why Source Through hicool?
- Direct factory pricing — typically 30–50% below European equivalents
- Authorized WKDL distributor with full manufacturer warranty
- Complete documentation: dimension drawings, airflow diagrams, wiring schematics
- Express delivery: stock models 5–7 days; custom options 12–15 days
- Spare parts readily available: fan motors, defrost heaters, temperature sensors
Browse DLS Side-Blow Coolers Products
| Product | Cooling Area | Refrigerant | Defrost Type | |
|---|---|---|---|---|
| WKDL DLS-100 Side-Blow Chiller — 100 m² | — | Ethylene Glycol, NH3, R22, R404A | Natural ventilation | View → |
| WKDL DLS-130 Side-Blow Chiller — 130 m² | — | Ethylene Glycol, NH3, R22, R404A | Natural ventilation | View → |
| WKDL DLS-140 Side-Blow Chiller — 140 m² | — | Ethylene Glycol, NH3, R22, R404A | Natural ventilation | View → |
| WKDL DLS-40 Side-Blow Chiller — 40 m² | — | Ethylene Glycol, NH3, R22, R404A | Natural ventilation | View → |
| WKDL DLS-50 Side-Blow Chiller — 50 m² | — | Ethylene Glycol, NH3, R22, R404A | Natural ventilation | View → |
| WKDL DLS-60 Side-Blow Chiller — 60 m² | — | Ethylene Glycol, NH3, R22, R404A | Natural ventilation | View → |
| WKDL DLS-80 Side-Blow Chiller — 80 m² | — | Ethylene Glycol, NH3, R22, R404A | Natural ventilation | View → |
View All DLS Side-Blow Coolers →
Related Pages
Related Products & Parts
Related Equipment
Guides & Articles
📩 Need a quotation? Send your requirements to sales@hiqool.com or request a quote online. We respond within 24 hours with pricing, lead time, and technical datasheets.
Model Comparison — 7 Models
Compare specifications across the full range. Click any model for detailed product page.
| Model | SKU | Cooling Area (m²) | Voltage | Fan Diameter (mm) | Fan Quantity | Fin Spacing (mm) | Defrost Type | Refrigerant | Mounting | HS Code | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| DLS-100 Side-Blow Chiller — 100 m² | HC-010402-053 | 100 | 380V 50Hz 3P | 400 | 3 | 4.5, 8 | Natural ventilation | Ethylene Glycol, NH3, R22, R404A | Wall side-blow | 8418.69 | |
| DLS-130 Side-Blow Chiller — 130 m² | HC-010402-054 | 130 | 380V 50Hz 3P | 400 | 4 | 4.5, 8 | Natural ventilation | Ethylene Glycol, NH3, R22, R404A | Wall side-blow | 8418.69 | |
| DLS-140 Side-Blow Chiller — 140 m² | HC-010402-055 | 140 | 380V 50Hz 3P | 400 | 5 | 4.5, 8 | Natural ventilation | Ethylene Glycol, NH3, R22, R404A | Wall side-blow | 8418.69 | |
| DLS-40 Side-Blow Chiller — 40 m² | HC-010402-056 | 40 | 380V 50Hz 3P | 300 | 2 | 4.5, 8 | Natural ventilation | Ethylene Glycol, NH3, R22, R404A | Wall side-blow | 8418.69 | |
| DLS-50 Side-Blow Chiller — 50 m² | HC-010402-057 | 50 | 380V 50Hz 3P | 300 | 2 | 4.5, 8 | Natural ventilation | Ethylene Glycol, NH3, R22, R404A | Wall side-blow | 8418.69 | |
| DLS-60 Side-Blow Chiller — 60 m² | HC-010402-058 | 60 | 380V 50Hz 3P | 300 | 3 | 4.5, 8 | Natural ventilation | Ethylene Glycol, NH3, R22, R404A | Wall side-blow | 8418.69 | |
| DLS-80 Side-Blow Chiller — 80 m² | HC-010402-059 | 80 | 380V 50Hz 3P | 400 | 3 | 4.5, 8 | Natural ventilation | Ethylene Glycol, NH3, R22, R404A | Wall side-blow | 8418.69 |
Side-Blow Cooler Selection Guide
Measure Available Space
DLS needs less depth (wall-to-unit) than DL/DD. Measure the clearance between your racking and wall/ceiling to confirm DLS fits.
Calculate Air Throw
DLS air throw ranges from 8m to 25m depending on model. Match to your corridor/tunnel length. For tunnels over 25m, use multiple units in series.
Choose Mount Type
Wall mount (standard) or ceiling mount (optional bracket). Wall mount is easier to install and service. Ceiling mount saves wall space for racking.
Specify Temperature & Refrigerant
DLS covers +5°C to -25°C. For lower temperatures, consider DJ series with side-discharge option. Standard freon compatible; ammonia on request.
Product Video
Video Coming Soon
A product video is being prepared. Subscribe to our YouTube channel to be notified.
Real Project Deliveries
How We Deliver
Send Your Requirements
Technical specifications, quantity, classification requirements, and delivery schedule. We respond with a detailed quotation within 24 hours.
Confirm & Order
Review our quotation with technical drawing, delivery schedule, and payment terms. We confirm factory slot upon deposit.
Factory Inspection
Full dimensional check, function test, and quality inspection before packing. Photo report included. Third-party or class witness inspection on request.
Ship & Support
Export packing, FOB/CIF delivery, complete documentation (CE, test report, O&M manual). Installation support and spare parts available.
Frequently Asked Questions
Need Help Selecting the Right Model?
Send us your product specifications and requirements. Our engineers will recommend the optimal solution and provide a detailed quotation within 24 hours.
Request Quotation