Factory-audited suppliers Class certificates from the maker · CCS · BV · ABS · DNV · LR · NK · KR · RINA · RS Est. 2015 · Taizhou, Jiangsu
sales@hiqool.com +86 523-8762-5500
Request Quote
DLS Side-Blow Cooler · 7 Models

DLS Series Side-Blow Coolers — WKDL Narrow-Space Evaporators

WKDL DLS Series side-blow unit coolers for narrow corridors, tunnel freezers, and space-constrained installations. 7 models with lateral air discharge.

CE · ISO 9001 (Manufacturer) Certificates with Goods Hicool Supply
7 Models Available
40–140 Cooling Area (m²)
CE · ISO Held by Manufacturer
14–28 Days Typical Delivery

How Do You Cool a Narrow Corridor or Tunnel Without Blocking the Passage?

Ceiling coolers need headroom that narrow corridors and processing tunnels often lack. Floor units block forklift lanes. The WKDL DLS Series side-blow evaporators mount flat against a wall and discharge air horizontally across the room, delivering effective cooling in spaces as narrow as 2 metres without sacrificing any usable floor or overhead clearance.

🔒 Log in or Register to view pricing

WKDL DLS Series — Side-Blow Evaporators for Narrow Spaces

The DLS Series is designed for applications where conventional ceiling or floor evaporators simply do not fit. Seven models span 1.5 kW to 12.0 kW, with a slim wall-mount profile (typically 250–400 mm depth) that keeps the unit tight to the wall while directing chilled air sideways across the room. This makes the DLS ideal for processing corridors, pre-cooling tunnels, packaging line enclosures, and ante-rooms between temperature zones.

All DLS units use copper tube / aluminium fin coils with fin spacing options of 4.5 mm, 6 mm, and 9 mm. Electric defrost is standard. The compact form factor uses single-row or dual-row fan arrangements to maintain a shallow profile while still achieving effective air throws of 4–10 metres. Wall-mount brackets are included, and optional ceiling-suspension kits are available for corridor installations where wall space is occupied by racking.

The DLS line is popular in food processing plants, pharmaceutical clean rooms, flower cold storage corridors, and supermarket display-adjacent buffer zones throughout Southeast Asia, Eastern Europe, and Africa.

Key Specifications

CE (Manufacturer’s Declaration)
Manufacturer’s ISO 9001

  • Operating Temperature — 0 °C to −25 °C
  • Cooling Capacity Range — 1.5 kW (DLS-15) to 12.0 kW (DLS-120)
  • Air Discharge — Side-blow horizontal, 4–10 m effective throw
  • Unit Depth — 250–400 mm (slim wall-mount profile)
  • Coil Construction — Copper tubes, hydrophilic aluminium fins
  • Fin Spacing — 4.5 mm / 6 mm / 9 mm
  • Defrost Method — Electric defrost standard
  • Fan Motor — External rotor, IP54, 220 V / 380 V 50 Hz
  • Refrigerants — R404A, R507A, R22, R134a

Model Range

Model Capacity (kW) Air Flow (m³/h) Fan Config Unit Depth (mm)
DLS-15 1.5 1,200 1 × 250 mm 250
DLS-25 2.5 2,000 1 × 300 mm 280
DLS-40 4.0 3,200 2 × 250 mm 300
DLS-60 6.0 4,800 2 × 300 mm 320
DLS-80 8.0 6,500 2 × 350 mm 350
DLS-120 12.0 9,000 3 × 350 mm 400

DLS (Side-Blow) vs DL (Ceiling) — Which Do You Need?

Feature DLS Side-Blow DL Ceiling
Mounting Wall-mount, side discharge Ceiling-mount, downward discharge
Room Shape Narrow corridors, tunnels (2–6 m wide) Standard rooms (4–12 m wide)
Headroom Needed Minimal (mounts at any height) 300–600 mm below ceiling
Air Throw 4–10 m horizontal 6–15 m downward/forward
Capacity Range 1.5–12 kW 1.0–21 kW
Temp Range 0 to −25 °C +5 to −25 °C

Rule of thumb: If your room is narrower than 4 metres or ceiling height is restricted, use the DLS. For standard rectangular cold rooms with adequate ceiling clearance, the DL is more cost-effective.

Common Applications

  • Processing corridors between production and cold storage areas
  • Pre-cooling tunnels for fruit and vegetables before packing
  • Narrow ante-rooms and air-lock spaces between temperature zones
  • Packaging line enclosures requiring side-directed cooling
  • Small pharmaceutical storage rooms with limited ceiling access

Recent Supply Example

A fruit export packing facility in Thailand ordered 12 × DLS-60 units for pre-cooling tunnels (3 m wide × 25 m long). Units were wall-mounted at 2.5 m height with 6 mm fin spacing for the high-humidity fresh produce environment. Delivered FOB Shanghai within 14 days at approximately USD 850 per unit. Total project value: ~USD 10,200.

Why Source Through hicool?

  • Direct factory pricing — typically 30–50% below European equivalents
  • Authorized WKDL distributor with full manufacturer warranty
  • Complete documentation: dimension drawings, airflow diagrams, wiring schematics
  • Express delivery: stock models 5–7 days; custom options 12–15 days
  • Spare parts readily available: fan motors, defrost heaters, temperature sensors

Browse DLS Side-Blow Coolers Products

Product Cooling Area Refrigerant Defrost Type
WKDL DLS-100 Side-Blow Chiller — 100 m² — Ethylene Glycol, NH3, R22, R404A Natural ventilation View →
WKDL DLS-130 Side-Blow Chiller — 130 m² — Ethylene Glycol, NH3, R22, R404A Natural ventilation View →
WKDL DLS-140 Side-Blow Chiller — 140 m² — Ethylene Glycol, NH3, R22, R404A Natural ventilation View →
WKDL DLS-40 Side-Blow Chiller — 40 m² — Ethylene Glycol, NH3, R22, R404A Natural ventilation View →
WKDL DLS-50 Side-Blow Chiller — 50 m² — Ethylene Glycol, NH3, R22, R404A Natural ventilation View →
WKDL DLS-60 Side-Blow Chiller — 60 m² — Ethylene Glycol, NH3, R22, R404A Natural ventilation View →
WKDL DLS-80 Side-Blow Chiller — 80 m² — Ethylene Glycol, NH3, R22, R404A Natural ventilation View →

View All DLS Side-Blow Coolers →

📩 Need a quotation? Send your requirements to sales@hiqool.com or request a quote online. We respond within 24 hours with pricing, lead time, and technical datasheets.

Model Comparison — 7 Models

Compare specifications across the full range. Click any model for detailed product page.

Model SKU Cooling Area (m²) Voltage Fan Diameter (mm) Fan Quantity Fin Spacing (mm) Defrost Type Refrigerant Mounting HS Code
DLS-100 Side-Blow Chiller — 100 m² HC-010402-053 100 380V 50Hz 3P 400 3 4.5, 8 Natural ventilation Ethylene Glycol, NH3, R22, R404A Wall side-blow 8418.69
DLS-130 Side-Blow Chiller — 130 m² HC-010402-054 130 380V 50Hz 3P 400 4 4.5, 8 Natural ventilation Ethylene Glycol, NH3, R22, R404A Wall side-blow 8418.69
DLS-140 Side-Blow Chiller — 140 m² HC-010402-055 140 380V 50Hz 3P 400 5 4.5, 8 Natural ventilation Ethylene Glycol, NH3, R22, R404A Wall side-blow 8418.69
DLS-40 Side-Blow Chiller — 40 m² HC-010402-056 40 380V 50Hz 3P 300 2 4.5, 8 Natural ventilation Ethylene Glycol, NH3, R22, R404A Wall side-blow 8418.69
DLS-50 Side-Blow Chiller — 50 m² HC-010402-057 50 380V 50Hz 3P 300 2 4.5, 8 Natural ventilation Ethylene Glycol, NH3, R22, R404A Wall side-blow 8418.69
DLS-60 Side-Blow Chiller — 60 m² HC-010402-058 60 380V 50Hz 3P 300 3 4.5, 8 Natural ventilation Ethylene Glycol, NH3, R22, R404A Wall side-blow 8418.69
DLS-80 Side-Blow Chiller — 80 m² HC-010402-059 80 380V 50Hz 3P 400 3 4.5, 8 Natural ventilation Ethylene Glycol, NH3, R22, R404A Wall side-blow 8418.69

Side-Blow Cooler Selection Guide

1

Measure Available Space

DLS needs less depth (wall-to-unit) than DL/DD. Measure the clearance between your racking and wall/ceiling to confirm DLS fits.

2

Calculate Air Throw

DLS air throw ranges from 8m to 25m depending on model. Match to your corridor/tunnel length. For tunnels over 25m, use multiple units in series.

3

Choose Mount Type

Wall mount (standard) or ceiling mount (optional bracket). Wall mount is easier to install and service. Ceiling mount saves wall space for racking.

4

Specify Temperature & Refrigerant

DLS covers +5°C to -25°C. For lower temperatures, consider DJ series with side-discharge option. Standard freon compatible; ammonia on request.

Product Video

Video Coming Soon

A product video is being prepared. Subscribe to our YouTube channel to be notified.

How We Deliver

1

Send Your Requirements

Technical specifications, quantity, classification requirements, and delivery schedule. We respond with a detailed quotation within 24 hours.

2

Confirm & Order

Review our quotation with technical drawing, delivery schedule, and payment terms. We confirm factory slot upon deposit.

3

Factory Inspection

Full dimensional check, function test, and quality inspection before packing. Photo report included. Third-party or class witness inspection on request.

4

Ship & Support

Export packing, FOB/CIF delivery, complete documentation (CE, test report, O&M manual). Installation support and spare parts available.

Frequently Asked Questions

Yes, DLS is specifically designed for this. The side-blow pattern projects cold air along the tunnel length, following the product conveyor direction. For tunnels at -25°C to -35°C, we recommend the DLS with 9mm fin spacing and electric defrost. For temperatures below -35°C, consider DJ series with optional side-discharge configuration.
Air throw ranges from 8m (smallest model) to 25m (largest). Actual effective throw depends on room temperature, load, and obstructions. For tunnels over 25m, install two or more DLS units in series — we provide spacing recommendations.

Need Help Selecting the Right Model?

Send us your product specifications and requirements. Our engineers will recommend the optimal solution and provide a detailed quotation within 24 hours.

Request Quotation
Factory Direct Verified manufacturers
Manufacturer Certificates Class / CE / ISO 9001, supplied with goods
14–28 Days FOB Chinese port
T/T or L/C Flexible payment
Qiangbin Zhu - Founder, Hicool Machinery

Qiangbin Zhu — Founder, Hicool Machinery

10+ years sourcing marine and industrial equipment from China's manufacturing base. Direct factory relationships, quality inspection, and complete documentation for classification society approval. Direct contact: sales@hiqool.com