DD Series Floor Coolers — WKDL Dual-Discharge Evaporators
WKDL DD Series floor-standing dual-discharge unit coolers for large frozen storage rooms. 13 models for -18°C to -25°C applications. CE-marked by the manufacturer, R22/R404A/R507/NH3 compatible.
Struggling to Get Even Airflow Across a Wide Freezer Room?
Ceiling-mounted coolers lose throw distance in rooms wider than 10–12 metres, creating warm spots that compromise product quality and trigger temperature alarms. The WKDL DD Series floor-mounted evaporators solve this with dual-discharge air throw reaching up to 25 metres, purpose-built for large, wide freezer rooms operating between −18 °C and −35 °C.
WKDL DD Series — Floor-Mounted Dual-Discharge Evaporators
The DD Series is engineered for large-format frozen storage where uniform temperature distribution is non-negotiable. Twelve models deliver cooling capacities from 3.5 kW to 35.0 kW, with dual-side air discharge creating a symmetrical airflow pattern that eliminates the dead zones common in wide rooms. Floor mounting also simplifies installation — no structural ceiling reinforcement required.
Construction uses copper tube / aluminium fin coils with 6 mm or 9 mm fin spacing optimised for low-temperature, low-humidity operation. Hot-gas defrost is standard on all DD models above 8 kW; electric defrost is standard on smaller models. Heavy-gauge galvanized steel casings with epoxy powder coat withstand the thermal stress of daily defrost cycles at −35 °C.
The DD line is the preferred choice for frozen meat warehouses, ice cream distribution centres, seafood blast-holding rooms, and cold chain 3PL operators throughout Southeast Asia, the Middle East, and Latin America.
Key Specifications
CE (Manufacturer’s Declaration)
Manufacturer’s ISO 9001
- Operating Temperature — −18 °C to −35 °C
- Cooling Capacity Range — 3.5 kW (DD-35) to 35.0 kW (DD-350)
- Air Discharge — Dual-side horizontal throw, 12–25 m effective range
- Coil Construction — Copper tubes, hydrophilic aluminium fins
- Fin Spacing — 6 mm / 9 mm (low-temp optimised)
- Defrost Method — Electric (≤8 kW) / Hot-gas (>8 kW standard)
- Fan Motor — External rotor, IP54, 380 V 3-phase 50 Hz
- Refrigerants — R404A, R507A, R22, R744 (CO₂ cascade compatible)
Model Range
| Model | Capacity (kW) | Air Flow (m³/h) | Fan Config | Air Throw (m) |
|---|---|---|---|---|
| DD-35 | 3.5 | 3,200 | 2 × 300 mm | 12 |
| DD-60 | 6.0 | 5,000 | 2 × 350 mm | 15 |
| DD-100 | 10.0 | 8,500 | 2 × 400 mm | 18 |
| DD-150 | 15.0 | 12,000 | 4 × 350 mm | 20 |
| DD-250 | 25.0 | 18,000 | 4 × 400 mm | 22 |
| DD-350 | 35.0 | 24,000 | 6 × 400 mm | 25 |
DD (Floor) vs DL (Ceiling) — Which Do You Need?
| Feature | DD Floor-Mounted | DL Ceiling-Mounted |
|---|---|---|
| Room Width | >8 m ideal | <12 m ideal |
| Temperature | −18 to −35 °C | +5 to −25 °C |
| Air Throw | 12–25 m dual-side | 6–15 m single-direction |
| Floor Space | Requires concrete pad | Zero floor impact |
| Installation | Simpler (no ceiling load) | Needs ceiling reinforcement |
| Best For | Wide freezers, heavy loads | Standard cold rooms |
Rule of thumb: If your freezer is wider than 8 metres and operates below −18 °C, the DD Series delivers the air throw and capacity you need. For rooms under 8 m wide or above −18 °C, the ceiling-mounted DL Series is more space-efficient.
Common Applications
- Large frozen meat storage warehouses (−25 °C) with room spans of 15–30 m
- Ice cream and frozen dairy distribution holding rooms (−28 °C)
- Seafood processing facility blast-holding zones (−30 °C to −35 °C)
- 3PL cold chain logistics centres with multi-chamber frozen storage
- Industrial frozen food packaging and palletizing areas
Recent Supply Example
A frozen seafood processor in Vietnam ordered 8 × DD-150 units for two new 1,200 m² freezer rooms operating at −28 °C. Units included hot-gas defrost valves and stainless steel drip pans. Delivered within 22 days FOB Ningbo at approximately USD 2,400 per unit. Total project value: ~USD 19,200.
Why Source Through hicool?
- Direct factory pricing — typically 30–50% below European equivalents
- Authorized WKDL distributor with full manufacturer warranty
- Complete documentation: GA drawings, refrigerant piping diagrams, electrical schematics
- Express delivery: stock models 7–10 days; custom configurations 15–20 days
- On-site commissioning support available for orders above 10 units
Browse DD Floor Coolers Products
| Product | Cooling Area | Refrigerant | Defrost Type | |
|---|---|---|---|---|
| WKDL DD-100 Freon Floor Unit Cooler — 100 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-12 Freon Floor Unit Cooler — 12 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-120 Freon Floor Unit Cooler — 120 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-140 Freon Floor Unit Cooler — 140 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-18 Freon Floor Unit Cooler — 18 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-22 Freon Floor Unit Cooler — 22 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-25 Freon Floor Unit Cooler — 25 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-30 Freon Floor Unit Cooler — 30 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-40 Freon Floor Unit Cooler — 40 m² | — | R22, R404A, R507 | Electric | View → |
| WKDL DD-50 Freon Floor Unit Cooler — 50 m² | — | R22, R404A, R507 | Electric | View → |
Related Pages
Related Products & Parts
Related Equipment
Guides & Articles
📩 Need a quotation? Send your requirements to sales@hiqool.com or request a quote online. We respond within 24 hours with pricing, lead time, and technical datasheets.
Model Comparison — 13 Models
Compare specifications across the full range. Click any model for detailed product page.
| Model | SKU | Cooling Area (m²) | Voltage | Fan Diameter (mm) | Fan Quantity | Fin Spacing (mm) | Defrost Type | Refrigerant | Mounting | HS Code | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| DD-100 Freon Floor Unit Cooler — 100 m² | HC-010402-001 | 100 | 380V 50Hz 3P | 400 | 3 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-12 Freon Floor Unit Cooler — 12 m² | HC-010402-002 | 12 | 380V 50Hz 3P | 230 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-120 Freon Floor Unit Cooler — 120 m² | HC-010402-003 | 120 | 380V 50Hz 3P | 400 | 3 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-140 Freon Floor Unit Cooler — 140 m² | HC-010402-004 | 140 | 380V 50Hz 3P | 400 | 4 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-18 Freon Floor Unit Cooler — 18 m² | HC-010402-005 | 18 | 380V 50Hz 3P | 330 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-22 Freon Floor Unit Cooler — 22 m² | HC-010402-006 | 22 | 380V 50Hz 3P | 330 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-25 Freon Floor Unit Cooler — 25 m² | HC-010402-007 | 25 | 380V 50Hz 3P | 330 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-30 Freon Floor Unit Cooler — 30 m² | HC-010402-008 | 30 | 380V 50Hz 3P | 330 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-40 Freon Floor Unit Cooler — 40 m² | HC-010402-009 | 40 | 380V 50Hz 3P | 330 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-50 Freon Floor Unit Cooler — 50 m² | HC-010402-010 | 50 | 380V 50Hz 3P | 330 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-60 Freon Floor Unit Cooler — 60 m² | HC-010402-011 | 60 | 380V 50Hz 3P | 400 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-7 Freon Floor Unit Cooler — 7 m² | HC-010402-012 | 7 | 380V 50Hz 3P | 330 | 1 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 | |
| DD-80 Freon Floor Unit Cooler — 80 m² | HC-010402-013 | 80 | 380V 50Hz 3P | 400 | 2 | 4, 6, 8, 9 | Electric | R22, R404A, R507 | Floor | 8418.69 |
How to Choose the Right DD Model
Assess Room Dimensions
DD is ideal for rooms wider than 8m. For narrow rooms (<6m), DL ceiling units provide better value. Calculate total cooling load based on room volume × insulation factor.
Select Fin Spacing
-18°C storage → 8mm. -22°C to -25°C → 10-12mm. Wider fins = less frost accumulation = longer run time between defrost cycles.
Choose Refrigerant System
Freon (R404A/R507): copper tube, lower cost. Ammonia (R717): steel tube, +15-20% cost but lower running expense at scale. Break-even at ~5,000 m² facility size.
Plan Floor Space
DD units need 1-2m clearance in front for airflow. Position away from forklift traffic lanes. We provide layout drawings for optimal placement.
Product Video
Video Coming Soon
A product video is being prepared. Subscribe to our YouTube channel to be notified.
Real Project Deliveries
How We Deliver
Send Your Requirements
Technical specifications, quantity, classification requirements, and delivery schedule. We respond with a detailed quotation within 24 hours.
Confirm & Order
Review our quotation with technical drawing, delivery schedule, and payment terms. We confirm factory slot upon deposit.
Factory Inspection
Full dimensional check, function test, and quality inspection before packing. Photo report included. Third-party or class witness inspection on request.
Ship & Support
Export packing, FOB/CIF delivery, complete documentation (CE, test report, O&M manual). Installation support and spare parts available.
Frequently Asked Questions
Need Help Selecting the Right Model?
Send us your product specifications and requirements. Our engineers will recommend the optimal solution and provide a detailed quotation within 24 hours.
Request Quotation